Repeated individual coding with RFID technologyCoding level "High" according to ISO 14119Connector M12, 8-poleGuard locking monitored1 Diagnostic outputmanual releaseBistable, motor-driven systemClamping force 10.000Release possible against lateral forces up to 300 NPL e / cat. 4 / SIL 3 for interlocking and guard locking functionTwo-channel input signal of the guard locking functionOperation on P/P- and P/N-switching outputsHigh tolerance to door misalignment
- Repeated individual coding with RFID technology
- Coding level "High" according to ISO 14119
- Connector M12, 8-pole
- Guard locking monitored
- 1 Diagnostic output
- manual release
- Bistable, motor-driven system
- Clamping force 10.000
- Release possible against lateral forces up to 300 N
- PL e / cat. 4 / SIL 3 for interlocking and guard locking function
- Two-channel input signal of the guard locking function
- Operation on P/P- and P/N-switching outputs
- High tolerance to door misalignment
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | AZM400Z-ST-I2-1P2P-DU |
Article number (order number) | 103044780 |
EAN (European Article Number) | 4030661563688 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
Approvals - Standards
| TÜV cULus FCC IC UKCA ANATEL |
General data
Standards | EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding | Individual coding, multiple teaching |
Coding level according to EN ISO 14119 | High |
Working principle | Magnetic field RFID |
Frequency band RFID | 125 kHz |
Transmitter output RFID, maximum | -6 dB/m |
Housing material | Light alloy die-casting |
Reaction time, switching off safety outputs via actuator, maximum | 100 ms |
Gross weight | 764 g |
General data - Features
Solenoid interlock monitored | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of diagnostic signals | 1 |
Number of safety contacts | 2 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Safety classification - Interlocking function
Performance Level, up to | e |
Category | 4 |
PFH value | 1.00 x 10⁻⁹ /h |
PFD value | 9.00 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Safety classification - Guard locking function
Performance Level, up to | e |
Category | 4 |
PFH value | 1.80 x 10⁻⁹ /h |
PFD value | 1.60 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical data
Interlocking principle | bistable |
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | Which have a lateral force Ftrans = 100 N: 100.000 operations |
Allowed distance interlock to actuator, minimum | 1 mm |
Allowed distance interlock to actuator, maximum | 7 mm |
Angular misalignment between solenoid interlock and actuator, maximum | 2 ° |
Minimum distance devices | 30 mm |
Holding force FZh in accordance with EN ISO 14119 | 10,000 N |
Holding force Fmax, maximum | 13,000 N |
Lateral force at bolt return, maximal (against locked door) | 300 N |
Note (Lateral force at bolt return) | Does not apply to emergency exit, Bowden cable and manual release |
Type of the fixing screws | 2x M6 |
Note (Type of the fixing screws) | Property class min. 10.9 |
Tightening torque of the screw | 8 Nm |
Note | The maximum tightening torque of the cover screw (cover triangle) is 0.55 Nm. |
Mechanical data - Connection technique
Termination | Connector M12, 8-pole, A-coded |
Mechanical data - Dimensions
Length of sensor | 46.7 mm |
Width of sensor | 77.8 mm |
Height of sensor | 156.7 mm |
Ambient conditions
Degree of protection | IP66 IP67 |
Ambient temperature | -20 ... +55 °C |
Storage and transport temperature | -40 ... +85 °C |
Relative humidity, maximum | 93 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Permissible installation altitude above sea level, maximum | 2,000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Electrical data
Operating voltage | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
No-load supply current I0, typical | 100 mA |
Operating current while bolt movement, peak | 600 mA / 100 ms |
Rated operating voltage | 24 VDC |
Required rated short-circuit current | 100 A |
External wire and device fuse rating | 2 A gG |
Time to readiness, maximum | 1,500 ms |
Switching frequency, maximum | 0.3 Hz |
Open / close cycle (motor), minimum | 3 |
Minimal average cycle time (with continuous operation) | 20 s |
Utilisation category DC-12 | 24 VDC / 0.05 A |
Electrical fuse rating, maximum | 2 A |
Electrical data - Control inputs Guard locking function
Designation, Control inputs | E1 und E2 (p-schaltend), E3 (n-schaltend) |
Switching thresholds of the control inputs | −3 V … 5 V (Low) 15 V … 30 V (High) |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Current consumption at 24V, minimum | 5 mA |
Current consumption at 24V, maximum | 10 mA |
Allowable discrepancy time (input), maximum | 10 s |
Test pulse interval, maximum | 40 ms |
Test pulse duration, maximum | 5 ms |
Permissible residual drive current | 1.5 mA |
Electrical data - Safety digital outputs
Designation, Safety outputs | Y1 and Y2 |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 2 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.25 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Test pulse interval, typical | 1000 ms |
Test pulse duration, maximum | 0.5 ms |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Electrical data - Diagnostic outputs
Designation, Diagnostic outputs | OUT |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 2 V |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.05 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Note | The diagnostic output are not safety relevant outputs! |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
PIN 1 | A1 Supply voltage UB |
PIN 2 | E1 Control input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT Diagnostic output |
PIN 6 | E3 Control input 3 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | E2 Control input 2 |
Scope of delivery
Scope of delivery | Actuator must be ordered separately. |
Accessory
Recommendation (actuator) | AZM400-B1 |
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.
Similar Products
Can't find the product you're looking for?
LET US HELP YOU
Can't Find the Product You're Looking For? Let Us Know, and We'll Source It for You!
Are you searching for products not listed on our website or out of stock? Let us know your requirements, and our expert team will contact you as soon as possible to find the most suitable solution for you.