Schmersal : AZM190-11/10RK-230VAC-131030203
AZM190-11/10RK-230VAC
AZM190-11/10RK-230VAC-131030203
Manual releaseThermoplastic enclosureLong lifeInterlock with protection against incorrect locking.89 mm x 178 mm x 41 mmActuating head can be repositioned by 4 x 90°2 cable entries M 20 x 1.5Wiring compartmentSlim design, particularly suitable for fitting on hinged doors, aluminium profiles and fencingSealing mechanism to prevent the ingress of dirtCut clamp termination
- Manual release
- Thermoplastic enclosure
- Long life
- Interlock with protection against incorrect locking.
- 89 mm x 178 mm x 41 mm
- Actuating head can be repositioned by 4 x 90°
- 2 cable entries M 20 x 1.5
- Wiring compartment
- Slim design, particularly suitable for fitting on hinged doors, aluminium profiles and fencing
- Sealing mechanism to prevent the ingress of dirt
- Cut clamp termination
Ordering data
Replacement article number | 101030203 |
Product type description | AZM190-11/10RK-230VAC |
Article number (order number) | 131030203 |
EAN (European Article Number) | 8905236105647 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
Approvals - Standards
| cULus CCC UKCA |
General data
Standards | BG-GS-ET-19 EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
Coding level according to EN ISO 14119 | Low |
Working principle | electromechanical |
Housing material | Glass-fibre, reinforced thermoplastic |
Gross weight | 480 g |
General data - Features
Power to unlock | Yes |
Manual release | Yes |
Number of actuating directions | 4 |
Number of auxiliary contacts | 1 2 |
Number of safety contacts | 1 |
Number of cable glands | 2 |
Safety classification |
Standards | EN ISO 13849-1 |
Performance Level, up to | c |
Category | 1 |
B10D Normally-closed contact (NC) | 2,000,000 Operations |
Note | Electrical life on request. |
B10D Normally-open contact (NO) | 1,000,000 Operations |
Note | at 10% Ie and ohmic load |
Mission time | 20 Year(s) |
Safety classification - Fault exclusion |
Please note: | Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. |
Performance Level, up to | d |
Category | 3 |
Note | for 2-channel use and with suitable logic unit. |
Mission time | 20 Year(s) |
Safety classification - Guard locking function
Performance Level, up to | e |
Note (Performance Level) | Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions. |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Holding force FZh in accordance with EN ISO 14119 | 1,950 N |
Holding force Fmax, maximum | 2,550 N |
Latching force | 20 N |
Positive break force, minimum | 20 N |
Actuating speed, maximum | 0.3 m/s |
Mounting | Screws |
Type of the fixing screws | 2x M5 |
Mechanical data - Connection technique
Cable entry | 2 x M20 x 1,5 |
Termination | Screw terminals |
Cable section, minimum | 0.5 mm² |
Cable section, maximum | 1.5 mm² |
Note | All indications including the conductor ferrules. |
Mechanical data - Dimensions
Length of sensor | 41 mm |
Width of sensor | 52 mm |
Height of sensor | 178 mm |
Ambient conditions
Degree of protection | IP65 IP67 |
Ambient temperature | -25 ... +55 °C |
Note (Relative humidity) | non-condensing non-icing |
Protection class | II |
Ambient conditions - Insulation values
Rated insulation voltage Ui | 250 VAC |
Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
Thermal test current | 4 A |
Rated control voltage | 230 VAC |
Required rated short-circuit current | 1,000 A |
Electrical power consumption, maximum | 8.5 W |
Switching element | NO contact, NC contact |
Switching principle | slow action, positive break NC contact |
Maximum switching frequency | 1,200 /h |
Material of the contacts, electrical | Silver |
Electrical data - Magnet control
Magnet switch-on time | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 50 ms |
Electrical data - Safety contacts
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 4 A |
Electrical data - Auxiliary contacts
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 4 A |
Other data
Note (applications) | sliding safety guard removable guard hinged safety guard |
Scope of delivery
Scope of delivery | Actuator must be ordered separately. |
Note
Note (Manual release) | front For maintenance, installation, etc. For manual release using triangular key M3 (included in delivery) |
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.
Similar Products
Can't find the product you're looking for?
LET US HELP YOU
Can't Find the Product You're Looking For? Let Us Know, and We'll Source It for You!
Are you searching for products not listed on our website or out of stock? Let us know your requirements, and our expert team will contact you as soon as possible to find the most suitable solution for you.