Schmersal : AZM 161 B ST1-AS A-101209091
AZM 161 B ST1-AS A
AZM 161 B ST1-AS A-101209091
Solenoid supply AUS AS interfaceActuator monitoredManual releaseSolenoid interlockThermoplastic enclosureHigh holding force 2000130 mm x 90 mm x 30 mmInterlock with protection against incorrect locking.Double-insulatedLong lifeIntegrated AS-Interface
- Solenoid supply AUS AS interface
- Actuator monitored
- Manual release
- Solenoid interlock
- Thermoplastic enclosure
- High holding force 2000
- 130 mm x 90 mm x 30 mm
- Interlock with protection against incorrect locking.
- Double-insulated
- Long life
- Integrated AS-Interface
Ordering data
Product type description | AZM 161 B ST1-AS A |
Article number (order number) | 101209091 |
EAN (European Article Number) | 4030661396446 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
Approvals - Standards
| IFA cULus ASi-SaW |
General data
Standards | EN IEC 62026-2 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 61508 |
Coding level according to EN ISO 14119 | Low |
Working principle | electromechanical |
Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Reaction time, maximum | 100 ms |
Gross weight | 450 g |
General data - Features
Power to lock | Yes |
Actuator monitored | Yes |
Manual release | Yes |
Integral system diagnostics, status | Yes |
Number of actuating directions | 3 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to | c |
Category | 1 |
PFH value | 1.14 x 10⁻⁶ /h |
Note (PFH-value) | up to max. 100,000 switching cycles/year |
Safety Integrity Level (SIL), suitable for applications in | 1 |
Mission time | 20 Year(s) |
Safety classification - Fault exclusion |
Please note: | Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. |
Performance Level, up to | d |
Category | 3 |
PFH value | 1.01 x 10⁻⁷ /h |
Note (PFH-value) | up to max. 100,000 switching cycles/year |
Safety Integrity Level (SIL), suitable for applications in | 2 |
Mission time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Actuating play in direction of actuation | 5.5 mm |
Holding force FZh in accordance with EN ISO 14119 | 2,000 N |
Holding force Fmax, maximum | 2,600 N |
Latching force | 5 N |
Actuating speed, maximum | 2 m/s |
Mounting | Screws |
Type of the fixing screws | 3x M6 |
Mechanical data - Connection technique
Connector position | Centre |
Termination | Connector plug M12, 4-pole, (A-coding) |
Mechanical data - Dimensions
Length of sensor | 30 mm |
Width of sensor | 130 mm |
Height of sensor | 90 mm |
Ambient conditions
Degree of protection | IP67 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 Hz ... 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | II |
Permissible installation altitude above sea level, maximum | 2,000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Electrical data
Maximum switching frequency | 1,000 /h |
Electrical data - AS Interface
Rated operating voltage | 26.5 ... 31.6 VDC (Protection against polarity reversal) |
AS-i Current consumption, maximum | 250 mA |
Electrical data - AS-Interface specification
AS-i Specification | Safety-Slave |
AS-i Version | V 2.1 |
AS-i Profile | S-7.B.F.E |
AS-i, IO-Code | 0x7 |
AS-i, ID-Code | 0xB |
AS-i, ID-Code1 | 0xF |
AS-i, ID-Code2 | 0xE |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 | Solenoid control |
AS-i Outputs, DO 1 | No Function |
AS-i Outputs, DO 2 | No Function |
AS-i Outputs, DO 3 | No Function |
AS-i Parameter bits, P0 | Actuator detected |
AS-i Parameter bits, P1 | Solenoid interlock locked |
AS-i Parameter bits, P2 | Magnet voltage in tolerance range |
AS-i Parameter bits, P3 | Error message - locking/unlocking of the solenoid interlock blocked |
Note (AS-i Parameter bits) | Set the parameter outputs to "1111" (0xF) FID: periphery error |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
Note (LED switching conditions display) | (1) LED yellow: Channel 2 / AS-i SaW Bit 2.3 (2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1 |
Other data
Note (applications) | sliding safety guard removable guard hinged safety guard |
Pin assignment
PIN 1 | AS-i + |
PIN 2 | n.c. |
PIN 3 | AS-Interface - |
PIN 4 | n.c. |
Scope of delivery
Scope of delivery | Actuator must be ordered separately. |
Note
Note (General) | Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. |
Note (Manual release) | For maintenance, installation, etc. For manual release using M5 triangular key, available as accessory |
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.
Similar Products
Can't find the product you're looking for?
LET US HELP YOU
Can't Find the Product You're Looking For? Let Us Know, and We'll Source It for You!
Are you searching for products not listed on our website or out of stock? Let us know your requirements, and our expert team will contact you as soon as possible to find the most suitable solution for you.